Helper General reference for SDO V6, V8 & V8E and RDO 8 & 10 opener Garage door opener does not operate at all with any control device Door reverses before reaching the floor or stops before reaching the fully opened position Door only operates from door control button but not from a transmitter Transmitter only works within short distance to the door Door opens but will not close Door not fully closed (only happens with some types of old rolling doors) Door opens or closes automatically when not in Auto Close Mode The motor runs when activated, but the door does not move Door not fully closed (only happens on some old rolling doors) POSSIBLE CAUSE: Aged rolling door installed with a new opener, but the tension of the door spring is not adjusted properly, the door bloomed when closing. SOLUTION: Re-tension the spring and re-set the opener margin force (see opener's Installation Instruction). Note: Information above is for general guidance only and can vary case by case. The suggested adjustments/solutions are summarised only. Please read the opener's Installation Instruction carefully. We strongly recommend you to contact a professional door service personnel or Herculift for more detailed solutions.
|